Precision Farming System Operators Manual
General PFadvantage Ag Leader Technology September 2003 1-8 Grain Flow Sensor Below is an example of a grain flow sensor. Your grain flow sensor m
Hiniker 8605 PFadvantage Application Rate Mode Ag Leader Technology September 2003 2-88 3. Press EXIT key to return to screen with ADVANCED SETTIN
PFadvantage Hiniker 8605 Ag Leader Technology Application Rate Mode September 2003 2-89 Settings on Hiniker 8605 No settings need to be made on t
Teejet 844 PFadvantage Application Rate Mode Ag Leader Technology September 2003 2-90 Cable attachment for Teejet 844 controller
PFadvantage Teejet 844 Ag Leader Technology Application Rate Mode September 2003 2-91 Setup for Teejet 844 controller A separate configuration of set
Teejet 844 PFadvantage Application Rate Mode Ag Leader Technology September 2003 2-92 Ground Speed Sensor: Set primary speed sensor to SERIAL. The m
PFadvantage Teejet 844 Ag Leader Technology Application Rate Mode September 2003 2-93 Avg. Speed Swath Application Rate between Scale Factor 0-25
Teejet 844 PFadvantage Application Rate Mode Ag Leader Technology September 2003 2-94 3. Exit back to main screen. a)Press FIELD key twice. b
PFadvantage Flowmeter Controller Ag Leader Technology Application Rate Mode September 2003 2-95 Cable attachment for Flow Meters Use these instructio
Flowmeter Controller PFadvantage Application Rate Mode Ag Leader Technology September 2003 2-96 Example of connections for a sprocket and shaft speed
PFadvantage Flowmeter Controller Ag Leader Technology Application Rate Mode September 2003 2-97Setup for Flow Meter A separate configuration of setti
PFadvantage General Ag Leader Technology September 2003 1-9 Moisture Sensor Below is an example of the moisture sensor mounted on the side of a cl
Flowmeter Controller PFadvantage Application Rate Mode Ag Leader Technology September 2003 2-98 Actual Rate Scale Factor: Set to 1.000. 2. Press C
PFadvantage Flowmeter Controller Ag Leader Technology Application Rate Mode September 2003 2-99 3. Exit back to main screen. a) Press FIELD ke
Direct Drive – Accu-Rate PFadvantage Application Rate Mode Ag Leader Technology September 2003 2-100 Cable attachment for Direct Drive of Rawson Acc
PFadvantage Direct Drive – Accu-Rate Ag Leader Technology Application Rate Mode September 2003 2-101 Dual Drive Rawson Direct Drive Adapter
Direct Drive – Accu-Rate PFadvantage Application Rate Mode Ag Leader Technology September 2003 2-102 Three Drive Rawson Module p.n. 2000987Raw
PFadvantage Direct Drive – Accu-Rate Ag Leader Technology Application Rate Mode September 2003 2-103 Setup for Direct Drive of Accu-Rate drive CAUT
Direct Drive – Accu-Rate PFadvantage Application Rate Mode Ag Leader Technology September 2003 2-104 Product: Press EDIT key. You can select an exi
PFadvantage Direct Drive – Accu-Rate Ag Leader Technology Application Rate Mode September 2003 2-105 Actual Rate Scale Factor: This setting is requ
Direct Drive – Accu-Rate PFadvantage Application Rate Mode Ag Leader Technology September 2003 2-106 1) Fill seed hopper with appropriate amount of
PFadvantage Direct Drive – Accu-Rate Ag Leader Technology Application Rate Mode September 2003 2-107 These settings appear when Controller Make =
General PFadvantage Ag Leader Technology September 2003 1-10 Header Height Sensor Below is an example of a header height sensor installed undernea
Direct Drive – Accu-Rate PFadvantage Application Rate Mode Ag Leader Technology September 2003 2-108 Manual Speed: Set this to your average speed i
PFadvantage Direct Drive – Accu-Rate Ag Leader Technology Application Rate Mode September 2003 2-109 4. Exit back to main screen. a) Press FIE
PFadvantage Calibration Overview Ag Leader Technology September 2003 3-1 Introduction You must calibrate the monitor for it to be accurate. The
Calibrating Distance PFadvantage (All Modes) Ag Leader Technology September 2003 3-2 Introduction You must calibrate distance for a primary or seco
PFadvantage Calibrating Distance Ag Leader Technology (All Modes) September 2003 3-3 Preparing to Calibrate Distance You must accurately measure a
Calibrating Distance PFadvantage (All Modes) Ag Leader Technology September 2003 3-4 Step Action 1 Use the UP or DOWN ARROW keys to set the actua
PFadvantage Calibrating Temperature Ag Leader Technology (Harvest Mode) September 2003 3-5 Introduction The moisture sensor contains a temperature
Calibrating Temperature PFadvantage (Harvest Mode) Ag Leader Technology September 2003 3-6 Step Action 1 Use the UP or DOWN ARROW keys to set t
PFadvantage Calibrating for Vibration (C1) Ag Leader Technology (Harvest Mode) September 2003 3-7 Introduction The PFadvantage must be calibrated
PFadvantage Setup Overview Ag Leader Technology September 2003 2-1 Important Notices The PFadvantage must be set up before field operation, but bef
Calibrating for Vibration (C1) PFadvantage (Harvest Mode) Ag Leader Technology September 2003 3-8 Step Action 1 Use the UP or DOWN ARROW keys t
PFadvantage Calibrating Moisture Ag Leader Technology (Harvest Mode) September 2003 3-9 Important Notes • You must calibrate the monitor for grain
Calibrating Moisture PFadvantage (Harvest Mode) Ag Leader Technology September 2003 3-10 Calibration MOISTURE CALIBRATION Procedure CHOOSE GRAIN:
PFadvantage Calibrating Moisture Ag Leader Technology (Harvest Mode) September 2003 3-11 Step Action 1 Use the UP or DOWN ARROW keys to set the
Calibrating Grain Weight PFadvantage (Harvest Mode) Ag Leader Technology September 2003 3-12 Before You Begin Calibrate the moisture before calibra
PFadvantage Calibrating Grain Weight Ag Leader Technology (Harvest Mode) September 2003 3-13 Step Action 1 With the combine stopped, the combine
Calibrating Grain Weight PFadvantage (Harvest Mode) Ag Leader Technology September 2003 3-14 Grain Weight To view the weight calibration screen p
PFadvantage Calibrating Grain Weight Ag Leader Technology (Harvest Mode) September 2003 3-15 Step Action 1 Use the UP or DOWN ARROW keys to set t
Calibrating Grain Weight PFadvantage (Harvest Mode) Ag Leader Technology September 2003 3-16 Step Action 8 Press the PERFORM CAL key to start the
PFadvantage Calibrating Grain Weight Ag Leader Technology (Harvest Mode) September 2003 3-17 Step Action 11 Good Calibration Results: If you have
Setup Overview PFadvantage Ag Leader Technology September 2003 2-2 Item Operating Mode Page New Leader Mark III/Mark IV Application Rate
Calibrating Grain Weight PFadvantage (Harvest Mode) Ag Leader Technology September 2003 3-18 Periodic Checks for Accuracy You should occasionally c
PFadvantage Calibrating Stop Height Ag Leader Technology (Harvest Mode) September 2003 3-19 Introduction The stop height is the height at which the
Calibrating Stop Height PFadvantage (Harvest Mode) Ag Leader Technology September 2003 3-20 Step Action 1 Use the UP or DOWN ARROW keys to select
Log Sheet September 2003 Field Load Actual % Indicated Dry Dry # Name # Name Crop Variety Date Lbs Moist Lbs Bu Acres Yield Com
Log Sheet September 2003 Field Load Actual % Indicated Dry Dry # Name # Name Crop Variety Date Lbs Moist Lbs Bu Acres Yield Com
Log Sheet September 2003 Field Load Actual % Indicated Dry Dry # Name # Name Crop Variety Date Lbs Moist Lbs Bu Acres Yield Com
Log Sheet September 2003 Field Load Actual % Indicated Dry Dry # Name # Name Crop Variety Date Lbs Moist Lbs Bu Acres Yield Co
PFadvantage Setup Overview Ag Leader Technology All Modes September 2003 2-3 Press the MENU key until you see the following keys on Order of
PFadvantage Operation Overview Ag Leader Technology September 2003 4-1 Important Notices The PFadvantage must be properly setup and calibrated. Ca
Fields and Loads PFadvantage All Modes Ag Leader Technology September 2003 4-2 Recommendations All the information recorded by the PFadvantage must
PFadvantage Fields and Loads Ag Leader Technology All Modes September 2003 4-3 Creating/Naming Fields and Loads Instructions for creating and namin
On Screen Map PFadvantage All Modes Ag Leader Technology September 2003 4-4 On Screen Map The PFadvantage mapping screen will display a coverage ma
PFadvantage On Screen Map Ag Leader Technology All Modes September 2003 4-5 The abbreviations for each mode and an example of file names are shown b
On Screen Map PFadvantage All Modes Ag Leader Technology September 2003 4-6 Setting Setting Options Default Comments Coverage Map ON, OFF ON ON – e
PFadvantage On Screen Map Ag Leader Technology All Modes September 2003 4-7Map Zoom display item. "a" is selected for auto zoom Example o
Area Counting PFadvantage All Modes Ag Leader Technology September 2003 4-8 Introduction In the bottom right corner of the display, the monitor alw
PFadvantage Area Counting Ag Leader Technology All Modes September 2003 4-9 Area Count Stop Beeps This setting determines how many times the monito
Setup Overview PFadvantage All Modes Ag Leader Technology September 2003 2-4 Order of Keys (Site Verification Mode) Press MENU key the display. Unti
Area Counting PFadvantage All Modes Ag Leader Technology September 2003 4-10 Adjusting Field Area If you know the exact field area, you can adjust th
PFadvantage Area Counting Ag Leader Technology All Modes September 2003 4-11 Calibration Step Action Procedure 1 Change the field to a field for w
Memory PFadvantage All Modes Ag Leader Technology September 2003 4-12 Introduction The PFadvantage has its own internal memory which stores all the
PFadvantage Memory Ag Leader Technology All Modes September 2003 4-13 Clear Load If you want to clear one load or all loads in a field, press CLEA
Marking PFadvantage All Modes Ag Leader Technology September 2003 4-14 Introduction You must have a memory card to do field marking. To perform fi
PFadvantage Marking Ag Leader Technology All Modes September 2003 4-15 Step Action 3 Press MARKS key. 4 Marks that are set as a Continuous Ma
Logging Map Data on Card PFadvantage All Modes Ag Leader Technology September 2003 4-16 Introduction The PFadvantage reads position information from
PFadvantage Logging Map Data on Card Ag Leader Technology All Modes September 2003 4-17 Setting the Logging Interval Press the SETUP key and CARD key
Logging Map Data on Card PFadvantage All Modes Ag Leader Technology September 2003 4-18 Type of Card Log file criteria AG LEADER™ ATA FLASH card A
PFadvantage Logging Map Data on Card Ag Leader Technology All Modes September 2003 4-19 Formatting Card The memory card must be formatted with a DO
PFadvantage Setup Overview Ag Leader Technology All Modes September 2003 2-5 Press the MENU key until you see on the following keys on Order o
Using a GPS Receiver PFadvantage All Modes Ag Leader Technology September 2003 4-20 Introduction You can use a GPS receiver and the PFadvantage to
PFadvantage Using a Radar Gun Ag Leader Technology All Modes September 2003 4-21 Introduction To more accurately measure ground speed on sloping fi
Using a Radar Gun PFadvantage All Modes Ag Leader Technology September 2003 4-22 Changing Speed Setting Press the SETUP key and VEHICLE key to view
PFadvantage Diagnostic Ag Leader Technology All Modes September 2003 4-23 Introduction The diagnostic screens provide troubleshooting and reference
Diagnostic PFadvantage All Modes Ag Leader Technology September 2003 4-24 GPS DIAGNOSTICS UTC TIME 00:00:00 Latitude 0000.0000 S Longitud
PFadvantage Diagnostic Ag Leader Technology All Modes September 2003 4-25 UTC TIME: Greenwich Mean Time (GMT), the current time Greenwich, Englan
Display Items PFadvantage Harvest Mode Ag Leader Technology September 2003 4-26 Introduction The PFadvantage has four display lines for viewing it
PFadvantage Display Items Ag Leader Technology Harvest Mode September 2003 4-27 Field and Load Totals When the following are displayed you can see
Display Items PFadvantage Harvest Mode Ag Leader Technology September 2003 4-28 SWATH This displays the cutting swath of the combine head. After yo
PFadvantage Display Items Ag Leader Technology Harvest Mode September 2003 4-29 DRY LBS/BU This displays the dry pounds per bushels that the monitor
Console Setup PFadvantage All Modes Ag Leader Technology September 2003 2-6 Introduction The console settings are general settings that apply to al
Summary PFadvantage Harvest Mode Ag Leader Technology September 2003 4-30 Introduction The summary screen shows totals and averages for your fields
PFadvantage Summary Ag Leader Technology Harvest Mode September 2003 4-31 Changing Field and Load The FIELD and LOAD key replace each other on t
Summary PFadvantage Harvest Mode Ag Leader Technology September 2003 4-32 Show Fields Press the SHOW FIELDS key to view a list of all the fields as
PFadvantage Summary Ag Leader Technology Harvest Mode September 2003 4-33 Show Loads Press the SHOW LOADS key to view a list of all the loads in th
Moisture Setting PFadvantage Harvest Mode Ag Leader Technology September 2003 4-34 Setting/Changing Moisture The operator can set the monitor to tak
PFadvantage Swath Setting Ag Leader Technology Harvest Mode September 2003 4-35 Introduction The PFadvantage has a separate swath setting for each
Grain Type PFadvantage Harvest Mode Ag Leader Technology September 2003 4-36 Introduction The monitor must be set on a grain type when harvesting.
PFadvantage Load Settings Ag Leader Technology Harvest Mode September 2003 4-37 Introduction The monitor records various settings for each load use
Load Settings PFadvantage Harvest Mode Ag Leader Technology September 2003 4-38 Move Load To move a load to another field or change grain type of l
PFadvantage Site Verification Ag Leader Technology September 2003 4-39 Introduction You can use the PFadvantage with a GPS receiver in a tractor o
PFadvantage Console Setup Ag Leader Technology All Modes September 2003 2-7 Operating mode The PFadvantage has the following operating modes: Grain H
Site Verification PFadvantage Ag Leader Technology September 2003 4-40Note: You should create a new file to log one kind of site verification data
PFadvantage Application Rate – Monitor/Control Ag Leader Technology Application Rate Mode September 2003 4-41 Introduction The PFadvantage console
Application Rate – Monitor/Control PFadvantage Application Rate Mode Ag Leader Technology September 2003 4-42 Logging Actual Rate and Area Counting A
PFadvantage Application Rate – Monitor/Control Ag Leader Technology Application Rate Mode September 2003 4-43 The On/Off designation indicates wheth
Display Items PFadvantage Application Rate Mode Ag Leader Technology September 2003 4-44 Introduction The PFadvantage has four display lines for vi
PFadvantage Display Items Ag Leader Technology Application Rate Mode September 2003 4-45 Application Rate Display Items Below are listed in order t
Display Items PFadvantage Application Rate Mode Ag Leader Technology September 2003 4-46 DRIVE RPM This instantaneous actual rpm of the Rawson Driv
PFadvantage Printing Field/Load Summary Ag Leader Technology All Modes September 2003 4-47 SMS Basic Mapping Software The primary method of obtaini
Checking Data Accuracy PFadvantage End of Season Ag Leader Technology September 2003 4-48 Before You Begin After harvest season ends, remove the mo
PFadvantage Checking Data Accuracy Ag Leader Technology End of Season September 2003 4-49 Step Action 3 Press CONTINUE when “PRESS CONTINUE TO RU
Card Setup PFadvantage All Modes Ag Leader Technology September 2003 2-8 Introduction If you are using a GPS receiver, all the GPS data must be log
Checking Data Accuracy PFadvantage End of Season Ag Leader Technology September 2003 4-50 Step Action 1 Press Menu Key, SETUP, and GRAIN key 2
PFadvantage Checking Data Accuracy Ag Leader Technology End of Season September 2003 4-51 Updating Field Maps If you are using the GPS receiver and
Updating Operating Program PFadvantage All Modes Ag Leader Technology September 2003 4-52 Introduction Ag Leader Technology will offer free operati
PFadvantage Updating Operating Program Ag Leader Technology All Modes September 2003 4-53 Updating from a Step Action Memory Card 1 Using a compu
Updating Operating Program PFadvantage All Modes Ag Leader Technology September 2003 4-54 Step Action 1 Install the PF Utilities program on your
PFadvantage Boundary Ag Leader Technology All Modes September 2003 4-55 Introduction Using the GPS receiver, you can create a boundary file in any
Boundary PFadvantage All Modes Ag Leader Technology September 2003 4-56 BOUNDARY SETUP Field F11:SMITH Current Boundary None Created On 02/
PFadvantage Boundary Ag Leader Technology All Modes September 2003 4-57 Step Action 1 Position the vehicle at a starting point on the outside of
Gridding PFadvantage Site Verification Mode Ag Leader Technology September 2003 4-58 Introduction To use this feature the PFadvantage must be in Si
PFadvantage Gridding Ag Leader Technology Site Verification Mode September 2003 4-59 Gridding a field If you have not created a boundary file for a
PFadvantage Card Setup Ag Leader Technology All Modes September 2003 2-9 FILES OPTIONS File Name 02081501.YLD File
Gridding PFadvantage Site Verification Mode Ag Leader Technology September 2003 4-60 Step Action 2 Press the UP or DOWN ARROW key to change t
PFadvantage Gridding Ag Leader Technology Site Verification Mode September 2003 4-61 F18: North 80 L1: DG Grid Spacing 330 f
Gridding PFadvantage Site Verification Mode Ag Leader Technology September 2003 4-62 F18 L1: DG Shift Grid N ACCEPT
PFadvantage Navigate Ag Leader Technology Site Verification Mode September 2003 4-63 Introduction Use the navigate function to return to a specific
Navigate PFadvantage Site Verification Mode Ag Leader Technology September 2003 4-64 Navigate using a grid file To navigate using a grid file compl
PFadvantage Navigate Ag Leader Technology Site Verification Mode September 2003 4-65 Step Action 1 Press the UP or DOWN ARROW key and set target ty
Navigate PFadvantage Site Verification Mode Ag Leader Technology September 2003 4-66 Navigating to point(s) You can not change any of the display i
PFadvantage Navigate Ag Leader Technology Site Verification Mode September 2003 4-67 Example of navigating to grid points
PFadvantage Troubleshooting Ag Leader Technology September 2003 6-1 Introduction Use the procedures on the following pages to troubleshoot, calibra
Card Setup PFadvantage All Modes Ag Leader Technology September 2003 2-10 Logging Hours Available/Logging Interval 1 sec 2 sec 3 sec Ag Lead
Troubleshooting PFadvantage Ag Leader Technology September 2003 6-2 Subject Mode Page SNR for the beacon being used is very low or the unit can
PFadvantage Troubleshooting Ag Leader Technology Harvest Mode September 2003 6-3 Problem Cause Solution Zero Flow in Bu/Hr or lbs/Hr.. Elevator sp
Troubleshooting PFadvantage Harvest Mode Ag Leader Technology September 2003 6-4 Problem Cause Solution Zero Flow in Bu/Hr or lbs/Hr.. The cab, d
PFadvantage Troubleshooting Ag Leader Technology Harvest Mode September 2003 6-5 Moisture is inaccurate. Dry moisture is set incorrectly. Display INS
Troubleshooting PFadvantage Harvest Mode Ag Leader Technology September 2003 6-6 Problem Cause Solution Bu/Ac or lbs/Ac Yield too high or low (cont
PFadvantage Troubleshooting Ag Leader Technology Harvest Mode September 2003 6-7Problem Cause Solution Bu/Ac or lbs/Ac Yield too high or low (cont.
Troubleshooting PFadvantage Harvest Mode Ag Leader Technology September 2003 6-8 Problem Cause Solution Bu/Ac or lbs/Ac Yield too high or low (cont
PFadvantage Troubleshooting Ag Leader Technology Harvest Mode September 2003 6-9 Problem Cause Solution High Yield Reading After Stopping C1 value
Troubleshooting PFadvantage Harvest Mode Ag Leader Technology September 2003 6-10Problem Cause Solution Incorrect Acre Counting. Incorrect swath S
PFadvantage Troubleshooting Ag Leader Technology Harvest Mode September 2003 6-11Problem Cause Solution Moisture Readings of 5% or Erratic. Bad con
PFadvantage Card Setup Ag Leader Technology All Modes September 2003 2-11 Copying Data to Log File To copy memory to log files that are not set as
Troubleshooting PFadvantage Harvest Mode Ag Leader Technology September 2003 6-12 Problem Cause Solution Moisture continually reads 5% with elevato
PFadvantage Troubleshooting Ag Leader Technology Harvest Mode September 2003 6-13 Problem Cause Solution Incorrect Grain Weight (lbs) Calibration
Troubleshooting PFadvantage Harvest Mode Ag Leader Technology September 2003 6-14 Problem Cause Solution Incorrect Temperature Reading Temperature
PFadvantage Troubleshooting Ag Leader Technology Harvest Mode September 2003 6-15 Problem Cause Solution Incorrect Distance and MPH Calibration for
Troubleshooting PFadvantage All Modes Ag Leader Technology September 2003 6-16 Problem Cause Solution Monitor will not power up Insufficient voltag
PFadvantage Troubleshooting Ag Leader Technology All Modes September 2003 6-17 Problem Cause Solution Differential correction fades in and out •
PFadvantage Reference Overview Ag Leader Technology September 2003 7-1 Section Contents Item Page Calculating Dry Bushels 7-2 Available Grain
Calculating Dry Bushels PFadvantage Ag Leader Technology September 2003 7-2 Calculating Dry Bushels The monitor uses the following equation to ca
PFadvantage Calculating Dry Bushels Ag Leader Technology September 2003 7-3 Example: 1 ------------- = 1.183 per
Creating, Naming Fields, Loads PFadvantage All Modes except App Rate Ag Leader Technology September 2003 2-12 Recommendations NOTE: If using Appli
Available Grain Types PFadvantage Ag Leader Technology September 2003 7-4 Available Grain Grain Type Dry lbs/bu Types Soybeans 60 (fixed) Corn
PFadvantage Compatible Hardware Ag Leader Technology September 2003 7-5 Memory Cards The following characteristics are required of memory cards y
Beacon Information PFadvantage Ag Leader Technology September 2003 7-6 Beacon Information In the USA, call 1-703-313-5900 for Coast Guard GPS suppo
PFadvantage Beacon Information Ag Leader Technology September 2003 7-7 Pacific Coast Location ID Baud Rate Frequency Appleton, WA 871 100 300 Ca
Beacon Information PFadvantage Ag Leader Technology September 2003 7-8 Canada Location Baud Rate Frequency Alert Bay, BC 200 309 Amphitrite Point,
PFadvantage Satellite Providers Ag Leader Technology September 2003 7-9 OMNISTAR Region Frequency Eastern USA 1556.825 Central USA 1554.497 We
System Wiring PFadvantage Ag Leader Technology September 2003 7-10 System Wiring Refer to the last page to see a table of the pin-outs of the combi
PFadvantage System Wiring Ag Leader Technology September 2003 7-11 Pin-Out of Port 2 This connector would typically be connected to an external cont
System Wiring PFadvantage Ag Leader Technology September 2003 7-12 Pin-Out of AUX Port 1 Pin Number Name Remarks 1 -- 2 -- * PFadvantage has
PFadvantage System Wiring Ag Leader Technology September 2003 7-13 Checking Header Sensor Connections To check the header sensor for electrical co
PFadvantage Creating, Naming Fields, Loads Ag Leader Technology All Modes except App Rate September 2003 2-13 Creating and Step Action Press the
System Wiring PFadvantage Ag Leader Technology September 2003 7-14 Signal PFadvantage Cab / Distrib. Power Ground Spd Elevator Spd Moisture Flo
PFadvantage Parts List Ag Leader Technology September 2003 8-1 Parts List for PFadvantage Monitor Kit Part Name/Description Part No. Quantity
PF3000 Installation Ag Leader Technology September 2003 9-1 PFAdvantage Monitor Mounting Bracket Installation Parts required for this procedure:
Antenna Installation PFadvantage Ag Leader Technology September 2003 9-2Antenna Installation Before mounting the GPS antenna on your vehicle, the us
PF3000 Installation Ag Leader Technology September 2003 9-3 Thick (1/8 in. or more) 9/32 in. bit and self-tapping bolt. Installing Antenna Follow
Installation PF3000 Ag Leader Technology September 2003 9-4 Routing the GPS Cable to the Cab You will need the following parts and tools to route
PFadvantage Index Ag Leader Technology September 2003 10-1 A Actual Load Weights, Entering ...3-15 Actu
Index PFadvantage Ag Leader Technology September 2003 10-2 Diagnostic Screens ...4-2
PFadvantage Index Ag Leader Technology September 2003 10-3Installing Antenna Bracket ...9-2 Ins
Creating, Naming Fields, Loads PFadvantage All Modes except App Rate Ag Leader Technology September 2003 2-14 Step Action 5 Creating Fields Press
Index PFadvantage Ag Leader Technology September 2003 10-4 Power Supply-120v to 12v ...2-2 Pri
PFadvantage Index Ag Leader Technology September 2003 10-5Target Files Creating...
Product Registration Ag Leader Technology stands by all new products with a 2-year limited warranty from the warranty start date. The warranty st
Index PFadvantage Ag Leader Technology September 2003 4 8/5/03 – Updated Aux 1 Port Pin-outs 2/4/04 – Updated warranty and registration
PFadvantage Creating, Naming Fields, Loads Ag Leader Technology All Modes except App Rate September 2003 2-15 Creating and Step Action Press th
Creating, Naming Fields, Loads PFadvantage All Modes except App Rate Ag Leader Technology September 2003 2-16 Step Action 4 Creating Loads Press
PFadvantage Marker Setup Ag Leader Technology All Modes September 2003 2-17 Introduction If you are using an external Field Marker ignore the instr
PFadvantage General Ag Leader Technology September 2003 1-1 Welcome Welcome to the Ag Leader Technology family. Ag Leader Technology is dedicated
Marker Setup PFadvantage All Modes Ag Leader Technology September 2003 2-18 Changing a Setting Step Action 1 Use the UP or DOWN ARROW keys to
PFadvantage GPS SetupAg Leader Technology All Modes September 2003 2-19 Introduction The GPS 4100 and GPS 1000 require no initial setup to begin f
GPS Setup PFadvantage (All Modes) Ag Leader Technology September 2003 2-20GPS SETUP NMEA MESSAGE GPS INPUT/OUTPUT BEACON DIFFERNTIAL SATELLITE D
PFadvantage GPS SetupAg Leader Technology All Modes September 2003 2-21 Satellite Selection If you will be using the satellite differential option
GPS Setup PFadvantage (All Modes) Ag Leader Technology September 2003 2-22 SATELLITE DIFFERENTIAL SETUP Differential Source Satellite
PFadvantage GPS SetupAg Leader Technology All Modes September 2003 2-23 SATELLITE DIFFERENTIAL SETUP Oministar Satellite Beacon Frequencies: East
GPS Setup PFadvantage All Modes Ag Leader Technology September 2003 2-24 SATELLITE DIFFERENTIAL SETUP Oministar Satellite Beacon Frequencies:
PFadvantage GPS SetupAg Leader Technology All Modes September 2003 2-25 SATELLITE DIFFERENTIAL SETUP Differential Source Satellite Diffe
GPS Setup PFadvantage All Modes Ag Leader Technology September 2003 2-26 SATELLITE DIFFERENTIAL SETUP RACAL Satellite Beacon Frequencies: North
PFadvantage GPS SetupAg Leader Technology All Modes September 2003 2-27 SATELLITE DIFFERENTIAL SETUP Differential Source Satellite Differen
General PFadvantage Ag Leader Technology September 2003 1-2 Limited Warranty Ag Leader Technology will repair or replace at no charge any component
GPS Setup PFadvantage All Modes Ag Leader Technology September 2003 2-28 GPS SETUP NMEA MESSAGE GPS INPUT/OUTPUT BEACON DIFFERNTIAL SATELLITE DIF
PFadvantage GPS SetupAg Leader Technology All Modes September 2003 2-29 BEACON SETUP Mode: Manual Channel 0 Frequency 300.0 Channel 1
Vehicle Setup PFadvantage Harvest Mode Ag Leader Technology September 2003 2-30 Introduction For each operating mode, there are different items to
PFadvantage Vehicle Setup Ag Leader Technology Harvest Mode September 2003 2-31 Changing a Setting Step Action 1 Use the UP or DOWN ARROW keys t
Vehicle Setup PFadvantage Harvest Mode Ag Leader Technology September 2003 2-32 Area count stop beeps This setting is for the number of times the mo
PFadvantage Vehicle Setup Ag Leader Technology Harvest Mode September 2003 2-33 Primary and Secondary speed sensor The monitor has four different pri
Grain Setup PFadvantage Harvest Mode Ag Leader Technology September 2003 2-34 Grain Setup NOTE: Grass Seed monitors are setup using the same proc
PFadvantage Grain Setup Ag Leader Technology Harvest Mode September 2003 2-35 Changing a Setting Step Action 1 Use the UP or DOWN ARROW keys to se
Grain Setup PFadvantage Harvest Mode Ag Leader Technology September 2003 2-36 Dry lbs / bu This setting is the pounds / bushel value that the monit
PFadvantage Grain Setup Ag Leader Technology Harvest Mode September 2003 2-37 Changing C11 Step Action 1 You must display the weight calibratio
PFadvantage General Ag Leader Technology September 2003 1-3 General Description The PFadvantage is a universal monitor/controller for crop product
Grain Setup PFadvantage Harvest Mode Ag Leader Technology September 2003 2-38 GRAIN CALIBRATION
PFadvantage Swath Setup Ag Leader Technology Harvest Mode September 2003 2-39 Introduction The swath setup screen is used to set the permanent, fu
Swath Setup PFadvantage Harvest Mode Ag Leader Technology September 2003 2-40 Changing a Setting Step Action 1 Use the UP or DOWN ARROW keys to
PFadvantage Swath Setup Ag Leader Technology Site Verification Mode September 2003 2-41 Introduction The swath setup screen is used to set the perm
Vehicle Setup PFadvantage Site Verification Mode Ag Leader Technology September 2003 2-42 Introduction For each operating mode, there are different
PFadvantage Vehicle Setup Ag Leader Technology Site Verification Mode September 2003 2-43 Press the UP or DOWN ARROW key to scroll down to highlight
Raven Controller (with Serial Port) PFadvantage Application Rate Mode Ag Leader Technology September 2003 2-44 Cable attachment for Raven controlle
PFadvantage Raven Controller (with Serial Port) Ag Leader Technology Application Rate Mode September 2003 2-45 APP RATE CONFIG PRODUCT CONTROLLER CHA
Raven Controller (with Serial Port) PFadvantage Application Rate Mode Ag Leader Technology September 2003 2-46 App Distance From GPS: Set to distanc
PFadvantage Raven Controller (with Serial Port) Ag Leader Technology Application Rate Mode September 2003 2-47 Avg. Speed Swath Application Rate be
General PFadvantage Ag Leader Technology September 2003 1-4 Figure 1: Front panel of the PFadvantage Arrow Keys T
Raven Controller (with Serial Port) PFadvantage Application Rate Mode Ag Leader Technology September 2003 2-48 Actual Rate Units: Ignore this setti
PFadvantage Mid-Tech Controller Ag Leader Technology Application Rate Mode September 2003 2-49 Cable attachment for Mid-Tech controllers that are co
Mid-Tech Controller PFadvantage Application Rate Mode Ag Leader Technology September 2003 2-50 Setup for Mid-Tech controllers that are connected to D
PFadvantage Mid-Tech Controller Ag Leader Technology Application Rate Mode September 2003 2-51 Units: Set to Units/Acre of application. Set to GALL
Mid-Tech Controller PFadvantage Application Rate Mode Ag Leader Technology September 2003 2-52 Actual Rate Scale Factor: This setting is required to
PFadvantage Mid-Tech Controller Ag Leader Technology Application Rate Mode September 2003 2-53 Set to ZERO if want rate outside field to be zero.
Mid-Tech Controller PFadvantage Application Rate Mode Ag Leader Technology September 2003 2-54 Activating Configuration and Setting .tgt Prescription
PFadvantage DICKEY-john Land Manager Ag Leader Technology Application Rate Mode September 2003 2-55 Cable attachment for DICKEY-john Land Manager or
DICKEY-john Land Manager PFadvantage Application Rate Mode Ag Leader Technology September 2003 2-56 Setup for a DICKEY-john Land Manager or Land Man
PFadvantage DICKEY-john Land Manager Ag Leader Technology Application Rate Mode September 2003 2-57 Product: Press EDIT key. You can select an exis
PFadvantage General Ag Leader Technology September 2003 1-5 Display and Display Selection Keys The PFadvantage has four display lines for viewing
DICKEY-john Land Manager PFadvantage Application Rate Mode Ag Leader Technology September 2003 2-58 Example: Tgt file in pints/ac of Treflan, Land M
PFadvantage DICKEY-john Land Manager Ag Leader Technology Application Rate Mode September 2003 2-59 3. Press EXIT key to return to screen with ADV
DICKEY-john Land Manager PFadvantage Application Rate Mode Ag Leader Technology September 2003 2-60 Activating Configuration and Setting .tgt Prescri
PFadvantage DICKEY-john Seed Manager Ag Leader Technology Application Rate Mode September 2003 2-61 Cable attachment for DICKEY-john Seed Manager or
DICKEY-john Seed Manager PFadvantage Application Rate Mode Ag Leader Technology September 2003 2-62 Setup for DICKEY-john Seed Manager or Vanguard V
PFadvantage DICKEY-john Seed Manager Ag Leader Technology Application Rate Mode September 2003 2-63 Product: Press EDIT key. You can select an exis
DICKEY-john Seed Manager PFadvantage Application Rate Mode Ag Leader Technology September 2003 2-64 Activating Configuration 2. Exit back to main s
PFadvantage Rawson Accu-Rate/Accu-Plant Ag Leader Technology Application Rate Mode September 2003 2-65 Cable attachment for Rawson Accu-Rate Control
Rawson Accu-Rate/Accu-Plant PFadvantage Application Rate Mode Ag Leader Technology September 2003 2-66 Cable attachment for Rawson Accu-Rate and See
PFadvantage Rawson Accu-Rate/Accu-Plant Ag Leader Technology Application Rate Mode September 2003 2-67 Cable attachment for Rawson Accu-Plant Contro
General PFadvantage Ag Leader Technology September 2003 1-6 When some display items (like swath) are selected, an up and down arrow symbol will ap
Rawson Accu-Rate/Accu-Plant PFadvantage Application Rate Mode Ag Leader Technology September 2003 2-68 Setup for Rawson Accu-Rate or Accu-Plant Contr
PFadvantage Rawson Accu-Rate/Accu-Plant Ag Leader Technology Application Rate Mode September 2003 2-69 Units: Set to Units/Acre of application. Se
Rawson Accu-Rate/Accu-Plant PFadvantage Application Rate Mode Ag Leader Technology September 2003 2-70 Nominal Rate: If the PF is not controlling th
PFadvantage Rawson Accu-Rate/Accu-Plant Ag Leader Technology Application Rate Mode September 2003 2-71 Dry fertilizer mode - Press MODE key on proc
Rawson Accu-Rate/Accu-Plant PFadvantage Application Rate Mode Ag Leader Technology September 2003 2-72 3. Exit back to main screen. a)Press FIEL
PFadvantage New Leader Controller Ag Leader Technology Application Rate Mode September 2003 2-73 Cable attachment for New Leader Mark III or Mark IV
New Leader Controller PFadvantage Application Rate Mode Ag Leader Technology September 2003 2-74 Setup for New Leader Mark III or Mark IV controllers
PFadvantage New Leader Controller Ag Leader Technology Application Rate Mode September 2003 2-75 Units: Set to Units/Acre of application. Set to TO
New Leader Controller PFadvantage Application Rate Mode Ag Leader Technology September 2003 2-76 Nominal Rate: If the PF is not controlling the rate
PFadvantage New Leader Controller Ag Leader Technology Application Rate Mode September 2003 2-77 Target Rate Outside Field: This only pertains to
PFadvantage General Ag Leader Technology September 2003 1-7 Area Count Switch The area count switch manually turns on and off area counting. When
New Leader Controller PFadvantage Application Rate Mode Ag Leader Technology September 2003 2-78 Settings on New Leader processor If the PF is co
PFadvantage Flexicoil Flexcontrol Ag Leader Technology Application Rate Mode September 2003 2-79 Cable attachment for Flexcontrol controller
Flexicoil Flexcontrol PFadvantage Application Rate Mode Ag Leader Technology September 2003 2-80 Setup for Flexcontrol controller A separate configur
PFadvantage Flexicoil Flexcontrol Ag Leader Technology Application Rate Mode September 2003 2-81 Ground Speed Sensor: Set primary speed sensor to SER
Flexicoil Flexcontrol PFadvantage Application Rate Mode Ag Leader Technology September 2003 2-82 Actual Rate Scale Factor: This setting is required
PFadvantage Flexicoil Flexcontrol Ag Leader Technology Application Rate Mode September 2003 2-83 3. Press EXIT key to return to screen with ADVANC
Flexicoil Flexcontrol PFadvantage Application Rate Mode Ag Leader Technology September 2003 2-84 d)If you will be using a target file, press EDIT T
PFadvantage Hiniker 8605 Ag Leader Technology Application Rate Mode September 2003 2-85 Cable attachment for Hiniker 8605
Hiniker 8605 PFadvantage Application Rate Mode Ag Leader Technology September 2003 2-86 Setup for Hiniker 8605 controller A separate configuration of
PFadvantage Hiniker 8605 Ag Leader Technology Application Rate Mode September 2003 2-87 Ground Speed Sensor: Set primary speed sensor to SERIAL. The